Hanna Instruments HI 2216 Digital, Portable pH-ISE-ORP Meter

Condition: New Brand new item from stock or on order from manufacturer
2 YEAR MANUFACTURER'S WARRANTY
Stock #:
N1023
Status:
Available In Stock (request a quote)
Dimensions (approx.):
9.2 x 8.7 x 4.3"H (outside)
Electrical:
12VDC (included) Volts,
Product Description The HI 2216 is a pH, ORP, ISE meter with five point pH calibration and 0.001 pH resolution. This instrument provides GLP capabilities to
allow for the storage and retrieval of all data regarding pH, ORP, and ISE calibration. HI 2216 can perform measurements using ORP electrodes in the mV scale and ISE electrodes in the ppm scale through the pH channel input. A relative mV feature is also provided.
- Up to five point pH calibration with seven standard buffers
- Up to two point ISE calibration with five standard solutions
- 0.001 pH resolution
- Calibration expiration reminder
- GLP features
- Automatic Temperature Compensation
- Manually log up to 200 records and interval log up to 500 records
- PC interface via USB

SPECIFICATIONS:

Ranges: pH -2.0 to 16.0 pH; -2.00 to 16.00 pH; -2.000 to 16.000 pH
mV ±999.9 mV (ORP); ±2000 mV (ORP)
ISE 0.001 to 19990 ppm
Temperature -20.0 to 120.0°C (-4.0 to 248.0°F)

Resolutions: pH 0.1 pH; 0.01 pH; 0.001 pH
mV 0.1 mV (±999.9 mV); 1 mV (±2000 mV)
ISE 0.001 (to 1.999 ppm); 0.01 (to 19.99 ppm); 0.1 (to 199.9 ppm); 1 (to 1999 ppm); 10 (to 19990 ppm)
Temperature 0.1°C

Accuracy: pH ±0.1 pH; ±0.01 pH; ±0.002 pH
mV ±0.2 mV (±999.9 mV); ±1 mV (±2000 mV)
ISE ±0.5% FS
Temperature ±0.2°C (excluding probe error)

pH Calibration: automatic, up to five point calibration with seven standard buffers available (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45),
and two custom buffers ISE Calibration: automatic, one or two points with five available buffers (0.1, 1, 10, 100, 1000 ppm)
Temperature Compensation: manual or automatic (with HI 7662 probe)
from -20.0 to 120.0 ºC (-4.0 to 248.0°F)
Data Logging: log on demand, 200 records; autologging, 500 records
Logging Interval: 5, 10, 30 seconds and 1, 2, 5, 10, 15, 30, 60, 120, 180 minutes
stability logging ("StAb")

Supplied with HI 1131B pH electrode, temperature probe, electrode holder, pH 4.01 and 7.07 buffer solution sachets, electrolyte solution (30 mL), cleaning solution sachet, 12 VDC adapter and instructions.
The following link provides additional information from the instruction manual or original manufacturer's brochure. Right-click to open the PDF in a new window or download it:
http://www.labequip.com/stock/pictures/n1023.pdf