Product Description
The 225ATS is Buck's educational model, which comes with two powered lamp brackets on the back of the instrument, and one internal bracket. Their simple optical design gives this system superior energy, and better results than double beam AA systems. Our unique design also allows our instruments to have a smaller footprint and a lower cost.
The Buck Scientific line of Atomic Absorption Spectrophotometers were designed to utilize the maximum energy of the single beam optical system. This allowed them to build a smaller, less expensive and more sensitive instrument. Background correction was achieved by inserting the deuterium lamp directly after the hollow cathode lamp.
A general rule of thumb for optical engineers is every time a mirror is introduced into a lightpath it deducts 10% of the energy. So in this case, less really is more!
With a 10" touchscreen computer on-board guiding you through your analysis, using an AA Spectrophotometer has never been easier! The All new Graphical User Interface utilizes five tabbed screens for; Analysis, controls, library, calibration, and samples. The 4 front facing USB ports make connecting a mouse and extracting data onto usb flash discs easy! Our Hideaway keyboard makes naming your samples easy and conveniently tucks in when not in use.
SPECIFICATIONS:
Wavelength Range: 190 to 900nm, Accuracy ± 0.2nm, Precision ± 0.1nm
Monochromator / Optics: 250mm Ebert mount, 600 lines/mm grating, 0.2-0.7-2.0nm bandpass
Hollow Cathode Lamp Supply: Triple HCL power supply; 3 to 75 mA peak in NORMAL mode..
Background Correction: Deuterium - In-Line (see-through) configuration, pulsed illumination, hot cathode, variable frequency, corrects from 190-350nm (0.7nm slit). Variable Giant Pulse - Self-reversing HCL currents up to 750 mA with pulse time from 10 to 200 microseconds, corrects from 190-900nm. The 205AAS Does not feature D2 Background correction
Burner / Nebulizer: Polypropylene spray chamber with pre-mix burner and high efficiency adjustable nebulizers (SS), Titanium burner heads for Air/Acetylene, Argon/Hydrogen and Nitrous Oxide/Acetylene operation.
Integration / Response Range: User select-able times from 0.5 to 10 seconds for continuous (flame) and transient (furnace, hydride) signals.
Calibration: Automatic, weighted least squares fit to 1st, 2nd, 3rd, or 4th order functions, up to 8 points.
Display: 10 Color touchscreen with Lynux OS
Output Modes: 4 USB ports
The following link provides additional information from the instruction manual or manufacturer's brochure. Click to open the PDF in a new window or right-click to download it:
Buck 225ATS Atomic Absorption Spectrophotometer or copy the following into your browser address window: labequip.com/stock/pictures/n1887.pdf
Made in USA.
This item ships from East Norwalk, CT.