Hanna Instruments HI 98198 Portable Oxygen Meter

Condition: New Brand new item from stock or on order from manufacturer
2 YEAR MANUFACTURER'S WARRANTY ON BASE UNIT; 1 YEAR ON PUMP & BURETTE
Alternate Names:
DO Meter
Stock #:
N1849
Dimensions (approx.):
7.3 x 3.6 x 1.4 in.H (outside)
Electrical:
4 x 1.5V AA batterie Volts,
Product Description
The HI98198 Optical Dissolved Oxygen Meter makes measuring the concentration of dissolved oxygen hassle-free. Optical DO technology doesn't require a minimum flow rate, so there is less drift in your readings. Perfect for the field or for the laboratory, the Quick Connect probe requires no membranes, no filling solution, and no warm-up time so you can measure without hesitation. Your meter comes complete in a rugged, custom carrying case for easy transportation.
~ Optical DO technology for fast and stable readings, even in tough environments.
~ Digital probe with Smart Cap Technology eliminates costly, tiresome membranes and solutions.
~ An IP67-rated waterproof, rugged body makes this portable meter ideal for field use.

The HI98198 measures dissolved oxygen levels in water using enhanced optical dissolved oxygen technology to ensure high levels of accuracy. With built-in methods and calculations for the measurement of Biological Oxygen Demand (BOD), Oxygen Uptake Rate (OUR), and Specific Oxygen Uptake Rate (SOUR), there is no need for manual conversions.

Superior Field Usability: An IP67-rated, waterproof meter means that bad weather, splashes, and dust won't stop you from taking important measurements. The HI98198 is built to withstand immersion in water of 1m for up to 30 minutes. A large display and back light feature ensure that all of your important information is easily visible, no matter the amount of light.
Universal Port: The ultra-versatile USB-C port integrates seamless transfer of data. There is no need for software- simply connect a USB-C and send your data as a .CSV to a memory stick, computer, or android device.
Quick Connect Probe: The Quick Connect fitting is designed for quick and easy installation of the DO probe. A watertight connection without threads make attaching and removing the probe simple.

Smart Cap Technology:
~ Automatic Cap Recognition - Hanna's Smart Caps feature a built-in RFID reader that is able to store important data, including manufacture date and first-use date for increased traceabilty.
~ Longer Life - Smart Caps last one year from the date of first use. Your meter will automatically count down from initialization and will have your meter remind you when it has expired with an on-screen message.
~ Aligned Right Every Time - An alignment key ensures that your Smart Cap is on correctly every time.

SPECIFICATIONS:
~ Oxygen, Dissolved Measurement Type: Optical
~ Oxygen, Dissolved Range: 0.00 to 50.00 mg/L / 0.0 to 500.0% saturation
~ Oxygen, Dissolved Resolution: 0.01 mg/L / 0.1% saturation
~ Oxygen, Dissolved Accuracy: 1.5% of reading ± 0.01mg/L for 0.00-20.00mg/L
____________________________ :5% of reading for 20.00-50.00mg/L
____________________________ :1.5% of reading ±0.1% for 00-200.0%
____________________________ :5% of reading for 200.0-500.0%
~ Oxygen, Dissolved Calibration: One or two points automatic calibration at 100% (8.26 mg/L) and 0% (0 mg/L)
________________________________:Single point manual using a value entered by the user in % saturation or mg/L.
~ Oxygen, Dissolved Temperature Compensation: Automatic from -5.0 to 50.0 °C (23.0 to 122.0 °F)
~ Barometric Pressure Compensation: Single point anywhere within pressure range
~ Salintiy Compensation: Automatic from 0 to 70 PSU (manually set)
~ Altitude Compensation: Automatic from 420 to 850 mmHg
~ Temperature Range: -5.0 to 50.0 °C (23 to 122 °F)
~ Temperature Resolution: 0.1 °C (0.1 °F)
~ Temperature Accuracy: ±0.3 °C (±0.4 °F)
~ Logging Type: On demand with 4000 records capability
~ Connectivity: USB-C
~ Automatic Shut-Off: User selectable: 5, 10, 30, 60 minutes or disabled
~ GLP: Yes- includes last 5 calibrations
~ Calibration Timeout Reminder: Yes- user selectable 'Calibration due' warning
~ Autoend: Yes
~ Display: LCD (back lighted display)
~ Battery Type / Life: 4 x 1.5V AA batterie (4 pcs.) / approx. 200 hours of continuous use without backlight (50 hours with backlight)

Your Optical Dissolved Oxygen Meter is equipped with everything you need for successful testing right out of the box: HI98198 is supplied with HI764113 optical DO probe with protective sleeve, HI7040 bi-component zero oxygen solution (230 mL + 30 mL), 100 mL plastic beaker (2), 1.8 m USB Type-C cable, 1.5V AA batteries (4), quality certificate, and instruction manual in a rugged carrying case with custom insert
The following link provides additional information from the manufacturer's brochure. Click to open the PDF in a new window or right-click to download it:
Hanna HI 98198 Portable Oxygen Meter or copy the following into your browser address window: labequip.ca/stock/pictures/n1849.pdf
Depending on inventory and destination, this item ships from Richmond Hill, ON or Laval, QC.
Request a Free Quote Right Now
Please fill in the form below to get a quote for the Hanna Instruments HI 98198 Portable Oxygen Meter: