Koehler Instrument K10200 / 10290 Automatic Aniline Point Apparatus

Condition: New Brand new item from stock or on order from manufacturer
1 YEAR MANUFACTURER'S WARRANTY
Stock #:
N981
Dimensions (approx.):
14.5"W x 8.5"D x 20.5 (outside)
Electrical:
115-240 Volts, 50/60 Hz,
Product Description
Aniline point is used to characterize pure hydrocarbons and to indicate the aromatic content of hydrocarbon mixtures. Equal volumes of aniline and sample or sample plus n-heptane are stirred together while being heated at a controlled rate. After the two phases become miscible, the mixture is cooled at a controlled rate and the temperature at which the two phases separate is the aniline point or mixed aniline point of the sample.
Features and Benefits:
~ Conforms to ASTM D611 and related specifications
~ For samples ranging from clear to very dark
~ Temperature range 0° to 150°C (32 to 302°F)
~ Digital temperature display
The Koehler K10200 Automatic Aniline Point Apparatus Performs aniline point and mixed aniline point determinations automatically by means of a modified thin film technique (ASTM D611 Method E). The sample-aniline mixture is directly heated by a platinum immersion heater and the aniline point is detected photoelectrically. Temperature is displayed on a large LED indicator. Built-in pressure regulator and solenoid valve permit the use of cooling air for quicker cooling cycles or to determine subambient aniline point temperatures. Aniline points as low as 0°C (32°F) can be determined with the use of refrigerated cooling air. Equipped with variable controls for heater, light source and stirrer speed. Cabinet exterior surfaces have a chemical resistant polyurethane enamel finish.
~ Conforms to the specifications of: ASTM D611; IP 2; ISO 2977; DIN 51775; FTM 791-3601; NF M 07-021
~ Testing Range: 0 to 150°C (32 to 302°F)
~ Temperature Display: 0-999.9°C

Included Accessories:
~ Standard Pyrex Test Cell with drain

Optional Accessories:

Catalog Number
250-000-33F ________ ASTM 33F Thermometer ____ -36.5 to +107.5°F
250-000-33C ________ ASTM 33C Thermometer ____ -38 to +42°C
250-000-34F ________ ASTM 34F Thermometer ____ 77 to 221°F
250-000-34C ________ ASTM 34C Thermometer ____ 25 to 105°C
250-000-35F ________ ASTM 35F Thermometer ____ 194 to 338°F
250-000-35C ________ ASTM 35C Thermometer ____ 90 to 170°C
K10210 ____ Pyrex Test Cell with drain
K10220 ____ Heating-Cooling Tube with platinum element
The following link provides additional information from the manufacturer's brochure. Click to open the PDF in a new window or right-click to download it:
Koehler K10200 / 10290 Automatic Aniline Point Apparatus or copy the following into your browser address window: labequip.ca/stock/pictures/n981.pdf
Made in USA.
This item ships from Bohemia, NY.