Koehler Instrument K11416 Reid Vapor Pressure Bath

Condition: New Brand new item from stock or on order from manufacturer
1 YEAR MANUFACTURER'S WARRANTY
Alternate Names:
Petroleum Bath, RVP
Stock #:
N717
Dimensions (approx.):
48 in.W x 22 in.D x 36 in.H (outside)
Electrical:
220-240 Volts, 60 Hz, 28A
Product Description
The 21 unit Koehler K11416 constant temperature Reid Vapor Pressure Bath immerses twenty-one test cylinders for vapor pressure tests on liquid products and liquefied petroleum gas (LPG). Electronic level control automatically maintains the proper immersion depth per ASTM specifications. Heating system employs a 6kW stainless steel heat exchanger with a heavy duty circulating pump to provide rapid heat-up, even heat distribution and ease of servicing. Convenient digital setpoint and display permits rapid selection of any bath liquid temperature within the operating range. A built-in over-temperature limit control protects against accidental overheating. Bath interior and internal components are constructed of heavy gauge stainless steel. Control panel is shielded by a hinged acrylic cover. Includes sturdy angle-iron base with corrosion resistant polyurethane finish. Order pressure gauges and cylinders separately. Digital electronic temperature control. Automatic water level control maintains proper immersion depth. Temperature Range: 212°F (100°C) ±0.2°F (±0.1°C). Bath Medium: 58 gal (219.5L) water. Heater Range: 0-6000W. Other accessories as listed below and on the attached specification sheet are available at additional cost.

Test apparatus for liquid products (ASTM D323) requires:
~ Test Cylinders, one or two-opening type
~ Pressure Gauges
~ Constant Temperature Bath
~ Bath Thermometer
~ Transfer Connection
~ Manometer
~ Manometer Adapter

Test apparatus for liquefied petroleum gases (ASTM D1267) requires:
~ Test Cylinders, two-opening type
~ Bleeder Valve Assemblies
~ Pressure Gauges
~ Constant Temperature Bath
~ Bath Thermometer
~ Flexible Tubing

50 Hz model for overseas use is also available and is slighlty less expensive - please inquire for pricing on K11415.
The following link provides additional information from the manufacturer's brochure. Click to open the PDF in a new window or right-click to download it:
Koehler K11416 Reid Vapor Pressure Bath or copy the following into your browser address window: labequip.ca/stock/pictures/n717.pdf
Made in USA.

ACCESSORIES:

OPTIONAL ACCESSORIES AT ADDITIONAL COST:
K11500 Reid Vapor Pressure Cylinder, 1-Opening Type
K11201 Reid Vapor Pressure Cylinder 2-Opening Type
K11202 Bleeder Valve Assembly for LPG tests for K11201 test cylinder
311-005-004 Range (psi/kPa): 0-5/35 Figure Intervals (psi/kPa): 0.5/5 Interval Graduations(psi/kPa): 0.05/0.2
311-015-002 Range (psi/kPa): 0-15/100 Figure Intervals (psi/kPa):1.0/10 Interval Graduations(psi/kPa): 0.1/1.0
311-030-002 Range (psi/kPa): 0-30/200 Figure Intervals (psi/kPa):5.0/20 Interval Graduations(psi/kPa): 0.5/2.0
311-060-002 Range (psi/kPa): 0-60/400 Figure Intervals (psi/kPa):5.0/50 Interval Graduations(psi/kPa): 0.2/2.5
311-100-002 Range (psi/kPa): 0-100/700 Figure Intervals (psi/kPa):10/50 Interval Graduations(psi/kPa): 0.5/2.5
311-250-001 Range (psi/kPa): 0-250/1750 Figure Intervals (psi/kPa):25/100 Interval Graduations(psi/kPa): 1.0/20
311-600-003 Range (psi/kPa): 0-600/4200 Figure Intervals (psi/kPa):50/250 Interval Graduations(psi/kPa): 2.0/25
K11401-RPS RVP Data Acquisition System, 115V 60 Hz
K11491-RPS RVP Data Acquisition System,230V 50/60 Hz
K11404-50 RVP Pressure Transducer, 0-50 psi
K11404-200 RVP Pressure Transducer, 0-200 psi
K11404-1000 RVP Pressure Transducer, 0-1000 psi
250-000-18F ASTM 18F Thermometer
Range: 94 to 108°F
250-000-18C ASTM 18C Thermometer
Range: 34 to 42°C
250-000-65F ASTM 65F Thermometer
Range: 122 to 176°F
250-000-65C ASTM 65C Thermometer
Range: 50 to 80°C
K11800 Sample Container with Cover Assembly
K11810 Transfer Connection: Consists of threaded brass cap, delivery tube and smpling tube. Use for removing liquid from the sample container in accordance with ASTM specifications
371-000-002 Liquid Manometer: Graduated in inches (0.1" div.). For checking pressure gauge reading of up to 15psi
K112B-1-0-12 Manometer Adapter Kit: Kit for attaching pressure gauge to liquid manometer for pressure verification
AS568-210 O-ring Seal: For coupling between air and gas chambers on K11500 and K11201 vapor pressure pressure vessels
AS568-113 O-ring Seal: For gauge and bleeder valve assembly connections on K11500 and K11201 vapor pressure pressure vessels
K40100 Flexible Tubing: Sulfur-free plastic lined tubing with 1/4" stainless steel and aluminum connectors. For charging LPG test cylinder.

Request a Free Quote Right Now
Please fill in the form below to get a quote for the Koehler Instrument K11416 Reid Vapor Pressure Bath: