Koehler Instrument K24880 Microscale (CCCFP) Closed Cup Flash Point Tester

Condition: New Brand new item from stock or on order from manufacturer
1 YEAR MANUFACTURER'S WARRANTY
Stock #:
N1795
Dimensions (approx.):
8.9 x 12.2 x 16.3 in.H (outside)
Electrical:
100-240 Volts, 50/60 Hz, 300W
Product Description
The Koehler K24880 Microscale Continuously Closed Cup Flash Point Analyzer is widely used in the flash point measurement of petroleum products,transformer oil, turbine oil, paint, perfumes, wood preservative oil, aromatic oil, animal and vegetable oil, pesticide emulsifier, high viscosity materials, plasticizers and other substances.
In addition, Pensky-Martens closed cup method and rapid equilibrium closed cup method are feasible on this instrument by changing parameters. The correlation between these is very well.

ASTM D6450 This test method covers the determination of the flash point of fuel oils, lube oils, solvents, and other liquids by a continuously closed cup tester. The measurement is made on a test specimen of 1 mL. This test method utilizes a closed but unsealed cup with air injected into the test chamber and is suitable for testing samples with a flash point from 10°C to 250°C.

ASTM D7094 This test method covers the determination of the flash point of fuels including diesel/biodiesel blends, lube oils, solvents, and other liquids by a continuously closed cup tester utilizing a specimen size of 2 mL, cup size of 7 mL, with a heating rate of 2.5 °C per minute. This test method utilizes a closed but unsealed cup with air injected into the test chamber and is suitable for testing samples with a flash point from 35 °C to 225 °C.

Conforms to the specifications of: ASTM D6450, ASTM D7094
Excellent Correlation to: ASTM D56, D93, ASTM D3828, EN ISO 3679/3680, ISO2719, SH/T 0768, SN/T 3077.1, SN/T 3077.2, DL/T 1354, GB/T 261, GB/T 21615, GB/T 5208, GB/T 21790
Temperature range: -30°C top 420°C(below 0°C external cryogenic recirculating tank is needed)
Heating rate: 2.5 ±0.3°C/min, 5.5 ±0.5°C/min, can be customized from 0.5üÄ°C/min to 12°C/min
Accuracy of temperature reading: ±0.1°C
Pressure range: 0kPa ~ 200kPa
Sample volume: 1ml or 2ml
Ignition method: high voltage electronic ignition
Stirring rate: can be customized from 50rpm to 300rpm
Interfaces: USB, RS 232, Ethernet

INCLUDES:
~ 1ml Sample Cup
~ 2ml Sample Cup
~ Stirrer
~ Pipette
~ Pipe
~ Touch Pen
~ Cleaning Brush
~ Power Cord

The following link provides additional information from the manufacturer's brochure. Click to open the PDF in a new window or right-click to download it:
Koehler K24880 Microscale (CCCFP) Closed-Cup Flash Point or copy the following into your browser address window: labequip.ca/stock/pictures/n1795.pdf
Made in USA.
This item ships from Bohemia, NY.
Request a Free Quote Right Now
Please fill in the form below to get a quote for the Koehler Instrument K24880 Microscale (CCCFP) Closed Cup Flash Point Tester: